Pompy ciepła do basenów
With rising demand to cut emissions, Zhongnuan, an air source heat pump manufacturer, offers efficient swimming pool heat pumps that capture air heat to warm water for indoor and outdoor pools.

All In One Swimming Pool Heat Pump
Zhongnuan’s All In One Swimming Pool Heat Pump offers efficient heating for small to medium pools with a rust-free, streamlined plastic casing perfect for coastal areas. Featuring smart WIFI control and high-quality components, it ensures constant comfort from 15°C to 45°C for year-round swimming.
- Rust-Free Casing: Plastic design resists corrosion, ideal for coastal use.
- Smart WIFI Control: Adjusts pool heat remotely via mobile phone.
- Constant Temperature: Maintains 15-45°C water for all-season comfort.
Parametry produktu
Model | ZNECO4 | ZNECO6 | ZNECO8 | ZNEC10 | |
Działająca temperatura otoczenia. Zakres | ℃ | -10℃~43℃ | |||
Outlet Water Temp. | ℃ | 15℃~40℃ | |||
Zasilanie | / | 230V/1Ph/50Hz | |||
Advised pool volume | m3 | 10~25 | 25~40 | 40~55 | 55~80 |
Testing Condition: Ambient air temperature 28℃(DB)/25.3℃(WB), inlet water temperature 26℃ | |||||
Wydajność grzewcza | kW/COP | 3.8/5.3 | 5.7/5.35 | 7.8/5.4 | 9.7/5.5 |
Maksymalny prąd | A | 3.28 | 4.87 | 6.61 | 11.7 |
Sprężarka | / | Toshiba | Toshiba | Panasonic | Panasonic |
Typ sprężarki | Obrotowy | Obrotowy | Obrotowy | Obrotowy | |
Wymiennik ciepła | / | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC |
Spadek ciśnienia wody | kpa | 12 | 12 | 15 | 15 |
Przepływ wody | m³/h | 3 | 3 | 4 | 5 |
Podłączenie rury wodnej | / | 50mm | 50mm | 50mm | 50mm |
Czynnik chłodniczy | / | R32 | |||
Hałas | dB(A) | 34 | 34 | 35 | 35 |
Ochrona elektryczna | / | Klasa I | |||
Ochrona mechaniczna | / | IPX4 | |||
Wymiar (szer. * gł. * wys.) | mm | 808*300*546 | 808*300*546 | 942*426*721 | 942*426*721 |
Rozmiar opakowania | mm | 940*400*700 | 940*400*700 | 1060*530*880 | 1060*530*880 |

Pompa ciepła do mini basenów
Zhongnuan’s Mini Swimming Pool Heat Pump is designed for small pools with a titanium tub-shell heat exchanger for durability. Featuring smart WIFI control, its compact size is 55% smaller than standard models, ensuring efficient heating for portable and residential use.
Parametry produktu
Model | ZNRJ-28R/N8-MIE | ZNRJ-40R/N8-MIE | |
Działająca temperatura otoczenia. Zakres | ℃ | 7°C~43°C | 7°C~43°C |
Outlet Water Temp. | ℃ | 15°C~40°C | 15°C~40°C |
Zasilanie | / | 220V/1Ph/50Hz | 220V/1Ph/50Hz |
Testing Condition: Ambient air temperature 28℃(DB)/25.3℃(WB), inlet water temperature 26℃ | |||
Wydajność grzewcza | kW/COP | 2.85/5.48 | 3.85/5.7 |
Maksymalny prąd | A | 3.6 | 4.5 |
Wymiennik ciepła | / | Titanium in PVC | Titanium in PVC |
Przepływ wody | m³/h | 1.5 | 2.5 |
Podłączenie rury wodnej | inch | 1" | 1" |
Czynnik chłodniczy | / | R32 | R32 |
Controller | / | LED | LED |
Hałas | dB(A) | 51 | 53 |
Ochrona elektryczna | / | Klasa I | Klasa I |
Ochrona mechaniczna | / | IPX4 | IPX4 |
Wymiar (szer. * gł. * wys.) | mm | 411*250*376 | 411*250*376 |
Rozmiar opakowania | mm | 475*290*445 | 475*290*445 |
Waga netto | kg | 25 | 28 |
Waga brutto | kg | 28 | 31 |

Eco-Friendly R290 Swimming Pool Heat Pump
The Zhongnuan Eco-Friendly R290 Swimming Pool Heat Pump uses R290 echo refrigerant for sustainable heating of medium-sized pools with a capacity range of 5-26 kW. Featuring inverter technology, it operates efficiently from -15°C to 43°C, delivering consistent pool warmth with eco-conscious performance.
Parametry produktu
Model | ZN70N9-IVSQ | ZN100N9-IVSQ | ZN120N9-IVSQ | ZN150N9-IVSQ | ZN240N9-IVSQ | ZN240SN9-IVSQ | |
Działająca temperatura otoczenia. Zakres | ℃ | -15°C -> 43°C | |||||
Zasilanie | / | 230V/1Ph/50Hz | 230V/1Ph/50Hz | 230V/1Ph/50Hz | 230V/1Ph/50Hz | 230V/1Ph/50Hz | 400V/3Ph/50Hz |
Testing Condition: Ambient Temp. 27℃ (80.6℉), Water Inlet 26℃ (78.8℉) / Outlet 28℃ (82.4℉), Relative Humidity 80% | |||||||
Wydajność grzewcza | kW/COP | 7.6/4.81 | 10.97/5.7 | 13.6/5.43 | 18.4/5.11 | 25.6/5.63 | 26.5/5.75 |
Testing Condition: Ambient Temp. 15℃ (59℉), Water Inlet 26℃ (78.8℉) / Outlet 28℃ (82.4℉), Relative Humidity 70% | |||||||
Wydajność grzewcza | kW/COP | 5.7/4.08 | 7.3/4.25 | 10.3/4.18 | 13.4/4.14 | 19.6/4.39 | 20/4.55 |
Maksymalny prąd | A | 10 | 10 | 15.3 | 16 | 35 | 16 |
Wymiennik ciepła | / | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC |
Spadek ciśnienia wody | kpa | 20 | 25 | 30 | 40 | 60 | 60 |
Przepływ wody | m³/h | 3 | 4 | 5 | 6 | 10 | 10 |
Podłączenie rury wodnej | / | 50mm | 50mm | 50mm | 50mm | 50mm | 50mm |
Czynnik chłodniczy | / | R290 | R290 | R290 | R290 | R290 | R290 |
Hałas | dB(A) | 49 | 49 | 49 | 50 | 51 | 51 |
Ochrona elektryczna | / | Klasa I | |||||
Ochrona mechaniczna | / | IPX4 | |||||
Wymiar (szer. * gł. * wys.) | mm | 980*411*609 | 980*411*609 | 1080*474*715 | 1080*474*715 | 1178*518*872 | 1178*518*872 |
Waga netto | kg | 46 | 49 | 62 | 63 | 94 | 94 |
Waga brutto | kg | 58 | 59 | 72 | 80 | 111 | 111 |

Commercial Swimming Pool Heat Pump
Zhongnuan’s Commercial Swimming Pool Heat Pump provides efficient heating for medium to large pools with a capacity range of 16-50 kW. Designed for commercial facilities like hotels and leisure centers, it supports customization of compressor, heating capacity, ambient temperature, and water temperature settings, ensuring reliable performance in cold weather for tailored B2B solutions.
Parametry produktu
Model | ZNRJ-170R/N2-YV | ZNRJ-210R/N2-YV | ZNRJ-260R/N2-YV | ZNRJ-350R/N2-YV | ZNRJ-450R/N2-YV | ZNRJ-500R/N2-YV | |
Działająca temperatura otoczenia. Zakres | °C | -10°C -> 43°C | |||||
Zasilanie | / | 220V/1Ph/50Hz | 380V/3Ph/50Hz | 380V/3Ph/50Hz | 380V/3Ph/50Hz | 380V/3Ph/50Hz | 380V/3Ph/50Hz |
Heating Capacity(A24W27) | kW/COP | 16.1/5.22 | 20.1/5.16 | 23.9/5.34 | 33.3/4.91 | 41.4/5.47 | 49.3/4.94 |
Maksymalny prąd | A | 16.1 | 7.9 | 9.3 | 12.6 | 15.8 | 18.2 |
Sprężarka | / | Sanyo | Sanyo | Sanyo | Sanyo | Sanyo | Sanyo |
Typ sprężarki | / | Przewijanie | Przewijanie | Przewijanie | Przewijanie | Przewijanie | Przewijanie |
Compressor Qty. | / | 1 | 1 | 1 | 2 | 2 | 2 |
Wymiennik ciepła | / | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC | Titanium in PVC |
Spadek ciśnienia wody | kpa | 16 | 16 | 16 | 18 | 18 | 18 |
Przepływ wody | m³/h | 5-8 | 6-10 | 6-12 | 8-15 | 8-15 | 8-15 |
Podłączenie rury wodnej | / | 50mm | 50mm | 50mm | 63mm | 63mm | 63mm |
Czynnik chłodniczy | / | R410a | |||||
Hałas | dB(A) | 60 | 60 | 60 | 61 | 61 | 61 |
Ochrona elektryczna | / | Klasa I | |||||
Ochrona mechaniczna | / | IPX4 | |||||
Wymiar (szer. * gł. * wys.) | mm | 752*690*765 | 752*690*965 | 752*690*965 | 1450*702*950 | 1450*702*1060 | 1450*702*1260 |
Rozmiar opakowania | mm | 840*750*900 | 840*750*1100 | 840*750*1100 | 1525*805*1110 | 1525*805*1220 | 1525*805*1420 |
Waga netto | kg | 108 | 111 | 112 | 240 | 250 | 260 |
Waga brutto | kg | 120 | 123 | 125 | 270 | 280 | 290 |
The lifespan of a swimming pool heat pump typically ranges from 10 to 20 years, depending on maintenance and usage conditions.
Some pool heat pumps can be used for cooling by reversing the operation, but this is less common and typically less efficient than heating.
Pool heat pumps are generally suitable for most climates but may require additional support in extremely cold conditions. They work best in mild to moderate climates where ambient air temperatures are sufficient for efficient heat transfer.
Choosing the right size involves considering factors such as pool volume, desired water temperature, ambient air temperature, and usage patterns. Consulting with us, will recommended for accurate sizing.